Switching the mode of GSM scales FILIP
GSM scales FILIP can work in two modes, and can be switched off permanently by a magnet:
- As simple scales in the mode DISP, which does not switch on GSM module and the weight and battery condition can be read only on red LED display. In this mode, regular measurements are carried out and stored in the scale’s memory according to set intervals, which can be adjusted in the GSM mode via SMS, e.g. "timer=60,0" – measurements will be carried out once an hour. If measuring is set as once per 24 hours, the capacity of scales memory can be used for records for more than 1,5 year. If you switch the scales into the mode GSM with activated chip SIM, and you will turn on WEB in the scales, the entire history will be downloaded on WEB server, and will have access to it. Switching from this mode to the mode GSM can be carried out by putting the magnet to the scales on the period longer than 10 seconds in the time, when the scales is active. On the display, there will be the text "FSLP" and the scales will turn off. By repeated putting the magnet you can wake up the scales, and it will work in the GSM mode.
- In GSM mode, the entire functionality of the scale is supported. If the SIM chip in the scale is not activated, the display will show the text "noOP" - mobile operator not available. If the SIM chip in the scale is active and the text "noSG" or "noOP" is displayed on the screen, the mobile operator's signal is likely weak. A stronger antenna should be installed or the scale should be switched to DISP mode. The scale will continue to take regular measurements even when the mobile operator is not available, and as soon as it becomes available, it will download the measured data from the scale to the web server, which will provide access to the data.
- Permanent switch-off of the scales can be done by putting the magnet to the scales for the period longer than 10 seconds, when the scales are active. On the display, there will be the text "FSLP" and the scales will turn off permanently. The switch-on can be carried out by repeated putting the magnet next to the scales.
- Switching the modes of the scales can be done also by means of SMS, if the scales is in the mode GSM. A command "reset=0" switches the scales from the mode GSM to the mode DISP.
The errors displayed on an LED display
Valid from image Beehive v3.32.009.
1. ErP1, ErP2, ErP3, ErP4, ErP5 - Weighing error for platform 1 or 2 or 3 or 4 or 5. There is no stable weight on the scale.
2. ErE1, ErE2, ErE3, ErE4, ErE5 - Vážna chyba váženia pre plošinu 1 alebo 2 alebo 3 alebo 4 alebo 5. Poškodený vážiaci senzor - tenzometer.
3. ErH1 - Chyba externej SRAM. Možná chyba v napájkovaní pamäti RAM - skratované piny.
4. ErH2 - Chyba RTCC. Nefunguje reálny čas - hodiny. Chyba hodinového kryštálu.
5. ErH3 - Chyba externej sériovej EEPROM. Chybné osadenie alebo zničenie EEPROM.
6. ErH4 - Chyba AD prevodníka Hx711 pre vážiacu plošinu 1 alebo 2 alebo 3 alebo 4 alebo 5. Nenačítava merané dáta z AD prevodníka.
7. ErH5 - Rezervované.
8. ErH6 - Rezervované.
9. ErH7 - Chyba akcelerometra. Chybný reset akcelerometra alebo chybné zapájkovanie Akcelerometra na plošnom spoji.
10. ErH8 - Rezervované.
11. ErS1 - Teplota Ti - teplota elektroniky je mimo rozsah. Menej ako -35 stupňov celzia alebo viac ako 65 stupňov celzia. Nie je nakalibrovaná.
12. ErS2 - Teplota Te - teplota tenzometrov je mimo rozsah. Menej ako -35 stupňov celzia alebo viac ako 65 stupňov celzia. Nie je nakalibrovaná alebo pripojený senzor teploty alebo zničený senzor teploty.
13. ErS3 - Rozdiel medzi teplotou Te a Ti je viac ako 10 stupňov celzia.
14. ErS4 - Chyba Te. Poškodený alebo chýbajúci senzor teploty alebo nenakalibrovaná teplota Te.
15. ErS5, ErS6, ErS7, ErS8, ErS9 - Chyba teploty pri kalibrácii hmotnosti pre plošinu 1 alebo 2 alebo 3 alebo 4 alebo 5.
16. CAL1 - Drevená vážiaca plošina 1 alebo 2 alebo 3 alebo 4 alebo 5 nie je nakalibrovaná alebo chybné ukončenie kalibrácie. FILIP-WG.
17. CAL2 - Plastová vážiaca plošina 1 alebo 2 alebo 3 alebo 4 alebo 5 nie je nakalibrovaná alebo chybné ukončenie kalibrácie. FILIP-PG.
18. CAL3 - Plastová vážiaca plošina 1 alebo 2 alebo 3 alebo 4 alebo 5 nie je nakalibrovaná alebo chybné ukončenie kalibrácie. FILIP-PBHG.
19. Cor - Zapnutá automatická tepelná korekcia tenzometrov alebo je tepelná konštanta korekcie nastavená na nulu. Cor1 - Zapnutá automatická tepelná korekcia tenzometrov a zároveň je korekčná konštanta prvej fázy korekcie nenulová. Pre kontrolu že bola spustená prvá fáza korekcie, ale nebola dokončená druhou fázou.
20. CorP - Automatická korekcia tenzometrov je v procese. Počas tejto doby sa váha nepripája do GSM siete.