SMS from phone to VILKO 2
Examples.

Description

 SMS VILKO 2 of the phone.
Examples.

  Connecting the device to the battery, Wake up with magnet. VILKO: Date 14.01.2014  Time 13:46:43 Battery=90,2% Signal strenght=65.0% Active: 30 min
TEL=1,1AA3 Setting of phone numbers in positions 1 through production code. Modem: Phone number is set

TEL=1,+491635123456

TEL=5,+4219089876543

Position adjustment (1-5) and phone number. number +421 - code country. Modem: Phone number is set
TEL=2,0 Deleting a preset phone number 2 of the memory scales. Modem: Phone number is set
TEL List Position Telephone numbers (only show the positions with set tel. Number). Modem: TELEPHONE NUMBERS: 1,+XXXxxx402174*2,+XXXxxx247574 *3,+XXX000000000
V Listing manufacturing data. VILKO: Version:Beehive:1*UM-G-B*v1*UMB-00400001AB5*UMB-004.00.00001AB5*Boot-WEB*v4.5*Image-Beehive*v3.17.305*2014.5.12*www.operchip.com*NOW-OS-v1.00*1*
SQ Listing of signal quality GSM network. VILKO: Signal strenght 65.0%
  Warning for weak signal GSM network. VILKO: Signal strenght 30.0%
TIME=DDMMRR,HHMMSS

Setting the date, time:

DD = day, MM = month, YY = year

HH = hour, MM = minute, ss = seconds

VILKO: Time is set

TZ=+3    TZ=0    TZ=-1

Setting the time zone GMT + 3 hours, GMT or GMT + 1 hour. These can be seen only with activated time synchronization over the Internet. Command "NTPE".

FILIP: Time zone is set

TZ

Set time zone.

FILIP: Time zone: GMT+3

NTPE

Switching on the time synchronization using NTP over the internet.

FILIP: NTP enable

NTPD

Disabling time synchronization using NTP over the internet.

FILIP: NTP disable

NTP=3.sk.pool.ntp.org

Set NTP server.

FILIP: NTP server is set

NTP

List settings for NTP time synchronization over the Internet.

FILIP: NTP server: Disable, 3.sk.pool.ntp.org

APN=1,internet,meno,heslo

APN=1,internet,meno

APN=1,internet

Internet connection settings to position 1. There are four positions. VILKO: APN is set
WON Turning on the Internet (sending data). VILKO: WEB active
WOFF Turning off the Internet (sending data) VILKO: WEB off
EON Enable e-mails. VILKO: Email active
EOFF Disable e-mails. VILKO: Email off
EMAIL=1,This email address is being protected from spambots. You need JavaScript enabled to view it. Setting up e-mail at position 1. 5 positions. VILKO: Email is set
EMAIL=1,0 Deleting the e-mail 1 of the scale memory. VILKO: Email is set
EMAIL Listing email settings. VILKO: Email: 1,This email address is being protected from spambots. You need JavaScript enabled to view it.
AON Enabling sending alarm messages. VILKO: ALARM active
AOFF Disabling sending alarm messages. VILKO: ALARM off
ACCON Enabling accelerometer. They must also be enabled alarms. Accelerometer: Enable
ACCOFF Disabling accelerometer. Accelerometer: Disable
ACC=2,250,100,0 Setting parameters of the accelerometer. Sensitivity: 2 g; The level of activation: 250mg; ODE: 100Hz; Duration: 0ms Accelerometer: Parameters is set
ACC

Listing of set parameters accelerometer.

Sensitivity: 2 g, 4 g, 8 g, 16 g

The level of activation: in milligrams

ODE: measurement speed.

Accelerometer: Enable, Sensitivity 16g, Threshold 5000 mg, ODR 100Hz, Duration 0 ms, Read ok
  Alarm from the accelerometer. Activated when moving equipment. Accelerometer: Active
CR=1,*100#* Setting the phone number for the automatic detection of the amount of credit in positions 1 to 4. Position 1 is universal.

Modem: Tel credit is set

CR Credit status.

TEXT – Podľa operátora

Modem: Credit: unknown

  Event of insufficient credits. Modem: Credit is 2,00 EUR
INFO Current status: W-weight, external temperature T, T2 - external temperature, humidity H, Battery - battery capacity.

VILKO: W=40,1kg*T=22,3C* T2=22,4C *H=56.0 %*Battery=91,3 %

SMSON Enabling sending SMS Info.     VILKO: SMS active
SMSOFF Disabling sending SMS Info. VILKO: SMS off
SMS=1,0700 Position adjustment (1-8) and time sending SMS info. VILKO: SMS is set
DSMS=1 Deleting individual (1-8) SMS Info. VILKO: SMS deleted
SMS Summary Exposure to Time Info SMS - Active SMS Info. VILKO: SMS:1,07:00:00* 2,13:00:00* 3,19:00:00*
  SMS by set times as an information SMS. VILKO: W=40,1kg*T=22,3C* T2=22,4C *H=56.0 %*Battery=91,3 %
TIMER=60,2 TIMER -each 60 minutes recorded measurements, each 60 x 2 = 120 min activates modem.         

VILKO: Timer is set

SET Listing setup time, enable or disable alarms, SMS text, Internet, email. Adjust the timing for measuring a GSM module, the threshold for sensors and parameters for the weight of the first. VILKO: Date 08.01.2014 09:12:00 *AlOff*SMSOn*WEBOn*Tim=15,x2* *TR=50,55* T2R=25,26*HR=60,65* WR=10,11* WR2=60,64*  Wmax=200.0 kg* Wtare=0.0 kg
SET2 Listing settings, time, weight 1, weight 2. VILKO: Date 08.01.2014 09:12:00 * W2R=10,11* W2R2=60,64*  W2max=200.0 kg* W2tare=0.0 kg* W3R=10,11* W3R2=60,64*  W3max=200.0 kg* W3tare=0.0 kg
WA=2 Activating the number of connected weighing platforms. 1-3. Weight: Active
WR=10,11 Range no. Weight of 1 - (kg) Weight W: Range is set
  ALARM SMS - Weight (kg). Weight W:  ALARM 64,5 kg
WR2=60,64 Range no. Weight of 2 - (kg). Weight W: Range is set
  ALARM SMS - Weight (kg). Weight W:  ALARM 64,5 kg
WT Entering TARA. Reset weight, although weight is on it. Weight W: TARE is set
WCT Cancel Tara. Returns the status as to production calibration. Weight W: TARE is canceled
W2R=10,11 Range no. Weight of 1 - (kg). Weight W2: Range is set
  ALARM SMS - Weight (kg). Weight W2:  ALARM 64,5 kg
W2R2=60,64 Range no. Weight of 2 - (kg). Weight W2: Range is set
  ALARM SMS - Weight (kg). Weight W2:  ALARM 64,5 kg
W2T Entering TARA. Reset weight, although weight is on it. Weight W2: TARE is set
W2CT Cancel Tara. Returns the status as to production calibration. Weight W2: TARE is canceled
W3R=10,11 Range no. Weight of 1 - (kg). Weight W3: Range is set
  ALARM SMS - Weight (kg). Weight W3:  ALARM 64,5 kg
W3R2=60,64 Range no. Weight of 2 - (kg). Weight W3: Range is set
  ALARM SMS - Weight (kg). Weight W3:  ALARM 64,5 kg
W3T Entering TARA. Reset weight, although weight is on it. Weight W3: TARE is set
W3CT Cancel Tara. Returns the status as to production calibration. Weight W3: TARE is canceled
TR=5,6 The temperature range for T – (oC) Temperature T: Range is set
  ALARM SMS – Temperature T – (oC) Temperature T: ALARM 24,1 C
T2R=23,24 The temperature range for T2 – (oC) Temperature T2: Range is set
  ALARM SMS - Temperature T2 -  (oC) Temperature T2: ALARM 24,2 C
HR=60,65 Humidity range for H - (%). Humidity H: Range is set
  ALARM SMS – Humidity H – (%) Humidity H: ALARM 66,1%
BR=30,100 Setting range for battery. 30% and 100% of capacity. Battery: Range is set
  Warning low voltage power accumulator. Battery: 29,9 % Battery is low
  Warning battery charge. Battery: 100,0 % Battery is full
  Contakt ALARM active. Detector 2: Active
  Contact ALARM inactive. Detector 2: End
SON Turning on the siren. The siren turns on automatically when activating the alarm contact. Siren: Active
SOFF Turning off the siren. The siren goes off and automatically 30 seconds after activation of the alarm contacts. Siren: Off
SAVE

User settings are saved.Phone numbers, URLs on the web,Mail, Email settings, Internet settings, sender names, names errors, names of commands, responses and events.

VILKO: Save OK
LOAD Retrieving user settings. VILKO: Load OK
CT=INFO,STATE Change text command. The first parameter is the old command, the second parameter of the new command. Modem: Command name is set
GCT=10 Listing command text from the position in the parameter. 5 commands. Modem: Commands: 10,CR;11,GCT=;12,CT=;13,DT=;14,AT=;
DT=Siren,Buzzer Change text sender. The first option old text, the second parameter new text. Modem: The name is set
AT=Battery is low, Acumulator is low Change text responses to events and alarms. The first option old text, the second parameter new text. Modem: Alarm name is set
  SMS command does not exist VILKO: Command does not exist
  Wrong format of SMS command. VILKO: Error command format
System Command !!!    
 US

Reprogramming weight with retention of all settings. Check the current version available at http://www.operchip.com/beehive/

Currently in the device detects the command "V".

It must be enabled web. Command "WON.

VILKO: Update Begin
UNS

Reprogramming balance settings to overwrite the factory settings. Check the current version available at http://www.operchip.com/beehive/

Currently in the device detects the command "V".

It must be enabled web. Command "WON".

VILKO: Update Begin
WZC

Calibration scales to zero. On weight must be no load.

Weight W: Zero calibration ok
W2ZC

Calibration scales 2 to zero. On weight must be no load.

Weight W2: Zero calibration ok
W3ZC

Calibration scales 3 to zero. On weight must be no load.

Weight W3: Zero calibration ok
WVC=80000

Calibration scales to 80 kg. Must be on weight 80 kg.

Weight W: Weight calibration ok
W2VC=100000 Calibration scales to 100 kg. Must be on weight 100 kg. Weight W2: Weight calibration ok
W3VC=80000 Calibration scales to 80 kg. Must be on weight 80 kg. Weight W3: Weight calibration ok
WM=150 Setting the maximum scales at 150 kg. Weight W: MAXIMUM weight is set
W2M=150 Setting the maximum scales at 150 kg. Weight W2: MAXIMUM weight is set
W3M=200 Setting the maximum scales at 200 kg. Weight W3: MAXIMUM weight is set
RESET Reset the device. It must be functional GSM module. FILIP: Reset Device